About

  • LARGE INVENTORY in Colorado.
  • FREE SAMPLING* & CATALOG policy!
  • NO MINIMUM ORDERS Required!
  • BLANKET ORDERS with Release Dates, allow our customers to obtain lower pricing!
  • SKILLED TECHNICAL DISTRIBUTORS
  • SUPERIOR PRODUCTS - Type NEMA 4x & 6 (Submersible)
  • 2D/3D CAD Available for Download!
  • FAST & FRIENDLY - Technical support!
  • SAME DAY SHIPPING: (Ground, Overnight, Next Day)
Sample Policy: Samples will be sent out once Sales has qualified the correct product(s) for your application.

Our Sealcon Ex Distributors can help your company with:

  • Quoting!
  • Catalog or Sample Requests!
  • Cross a Competitive Part!
  • Downloading 2D/3D CAD Models!




Why not offer the best solution? If you want to solve a Cable Gland, Cable Glands requirement – Don’t settle for less!

If you are looking for a cord grip to seal a connection in a dust tight, hose down, or even a submersible application – the Sealcon design with its Type NEMA 4X and 6 (IP68 and IP69K) and 150 PSIG pressure rating as well as V0 flammability rating according to UL 94, is unsurpassed by others.

Where to use our Products:
hazardous Cable Gland areas, HAZLOC, Drill Ships, Platforms, Barges, On/Offshore Rigs, Mining ,Frac Trucks, Measurement, Winches, Workboat, Pumps, Turbines, Compressorand, Mobil Equipment, Telemetry (EMI),Communication areas, Rig Lighting, Low Temp, Control Panels, EMI/RFI and many more Industries.



CABLE GLANDS FOR HAZARDOUS (EXPLOSION) AREAS

  • EXIOS Non-Armored +Barrier UL: Cable glands are used in Drill Ships, Platforms, Barges, On/Offshore Rigs and Mining.
    Temp: -13°F to 185°F (-25°C to 85°C)
    Approvals:UL.
    Protection & Markings:
    UL 2225 / UL 514B / CSA 22.2
    Class I, Div 1, Groups C, D
    Class I, Div 2, Groups C, D
    Class II, Div 1, Groups E, F & G
    Class II, Div 2, Groups E, F & G
    Class I, Zone 1, AEx d IIB
    Class III

  • EXIOS Armored + Standard: Cable glands are used in Frac Trucks, Measurement, Winches, Workboat, Pumps, Turbines, Compressor.
    Temp: -76°F to 221°F (-60°C to 105°C)
    Approvals: ATEX IECEx, CSA/ cUS, ABS, DNV, German Lloyd, Inmetro, PCT(Gost).
    Protection & Markings:
    Class I, Div 2 Groups A,B,C,D
    Class II, Div 1 & 2 Groups E,F,G
    Class I, Zone 1 AEx de IIC Gb
    Zone 20 AEx ta IIIC, T125°C Da
    II 2G Ex d e IIC Gb
    II 1D Ex ta IIIC Da

  • EXIOS Armored + Barrier: Cable glands are used in Drill Ships, Platforms, Barges, On/Offshore Rigs, Mining.
    Temp: -76°F to 185°F (-60°C to 85°C)
    Approvals: ATEX IECEx, CSA/ cUS, ABS, DNV, German Lloyd, Inmetro, PCT(Gost).
    Protection & Markings:
    Class I, Div 2 Groups A,B,C,D
    Class II, Div 1 & 2 Groups E,F,G
    Class I, Zone 1 AEx de IIC Gb
    Zone 20 AEx ta IIIC, T125°C Da
    II 2G Ex d IIC Gb / Ex e IIC Gb
    II 1D Ex ta IIIC Da IP 66/67/68
    I M2 Ex d I Mb / Ex e I Mb

  • EXIOS Armored + MZ Clamp: Cable glands are used in Mobil Equipment, Telemetry (EMI),Communication areas.
    Temp: -76°F to 221°F (-60°C to 105°C)
    Approvals: ATEX IECEx, CSA/ cUS, ATEX IECEx.
    Protection & Markings:
    Class I, Div 2 , Groups A,B,C,D
    Class II, Div 1 & 2 Groups E,F,G
    Class I, Zone 1 AEx de IIC Gb
    Zone 20 AEx ta IIIC, T125°C Da
    II 2G Ex d e IIC Gb
    II 1D Ex ta IIIC Da

  • EXIOS Non-Armored + A2F: Cable Glands for non-armored cables are used in Rig Lighting, Low Temp, Control Panels, EMI/RFI.
    Temp: -76°F to 221°F (-60°C to 105°C)
    Approvals: CSA/cUS, ATEX IECEx, ABS, DNV, German Lloyd, Inmetro, PCT(Gost).
    Protection & Markings:
    Class I, Div 2 , Groups A,B,C,D
    Class II, Div 1 & 2 , Groups E,F,G
    Class I, Zone 1, AEx de IIC Gb
    Zone 20, AEx ta IIIC, T125°C Da
    II 2G Ex d e IIC Gb
    II 1D Ex ta IIIC Da

  • Amored Ex-d Non-Armored Ex-e & Ex-d

    EXIOS standard Explosion Proof Cable Glands
    (YE and YZ)


    Nylon/Nickel Plated Brass

    (Standard/Elongated Threads)

    Nylon/Nickel Plated Brass

    (Multi-Hole & Romex)

    Clamping (MZ)

    (High Performance)
    EXIOS Barrier Compound Glands
    (YP & YU)

    Stainless Steel

    (INOX/PVDF)

    A2F

    Ex-d Explosion Proof
    (YA - in Brass, Nickel Plated Brass, INOX)

    Features & Benefits
    • Liquid Tight - Submersible to 300 ft. - Type NEMA 4x & 6 (IP 68 / IP 69K)
    • Highest Pressure Rating - Patented form seal meets 150 PSIG (10 BAR)
    • Flame protected - V0 Rated According to UL 94
    • Halogen- and Phosphorous-Free Materials
    • Safety - Ratchet to prevent Dome from coming loose under vibration
    • Large Selection - Cable Range from .08" (2 mm) to 3.54" (90 mm)
    • Non-Corrosive - Resistant to salt water, weak acids, weak alkalis, alcohol, esters, ketones, ether, gasoline, mineral, animal & vegetable oil.
    • Durable - Rugged Construction
    • Environmentally Compliant - RoHS & Deca BDE
    Strain-Relief Information


    Nylon Information
    Nylon: Detailed Info
    Nickel Plate Brass - Cable Gland
    Nickel Plated Brass: Detailed Info

    Product Benefits
    • Applications
    • Large Cable Range
    • Time Saving Installation
    • Liquid Tight (Type NEMA 4x & 6)
    • Non-Corrosive
    • Approvals: UL, UR, CSA, VDE, CE, EX, ATEX
    • RoHS Compliant
    • V0 flammability rating / halogen & phosphorous-free - unsurpassed!
    • Concentric O-Ring Groove
    • Overlapping Splines
    • Patented Recess and High Performance Form Seal



    Office Hours: Monday thru Friday, 7:30 A.M. - 4:30 P.M. (MST)

    Email: (info@sealconex.com)